TABLE III. Group A inspection for device type 02- Continued.
Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
D0 |
D1 |
D2 |
D3 |
D4 |
D5 |
D6 |
GND |
D7 |
G |
A |
B |
C |
w |
Y |
VCC |
Min |
Max |
Unit |
||||
9 TC = 25°C " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
tPHL1 " " |
3003 (Fig 4) " |
73 74 75 |
GND " " |
5.0 V |
5.0 V |
5.0 V |
GND " " |
GND " " |
IN GND GND |
GND IN GND |
GND GND IN |
OUT " " |
5.0 V " " |
A to w B to w C to w |
6 " " |
32 " " |
ns " " |
|||||
tPLH1 " " |
" " " |
76 77 78 |
" " " |
5.0 V |
5.0 V |
5.0 V |
" " " |
" " " |
IN GND GND |
GND IN GND |
GND GND IN |
" " " |
" " " |
A to w B to w C to w |
" " " |
29 " " |
" " " |
||||||
tPHL2 " " |
" " " |
79 80 81 |
" " " |
5.0 V |
5.0 V |
5.0 V |
" " " |
" " " |
IN GND GND |
GND IN GND |
GND GND IN |
OUT " " |
" " " |
A to Y B to Y C to Y |
" " " |
40 " " |
" " " |
||||||
tPLH2 " " |
" " " |
82 83 84 |
" " " |
5.0 V |
5.0 V |
5.0 V |
" " " |
" " " |
IN GND GND |
GND IN GND |
GND GND IN |
" " " |
" " " |
A to Y B to Y C to Y |
" " " |
39 " " |
" " " |
||||||
tPHL3 tPLH3 tPHL4 tPLH4 |
" " " " |
85 86 87 88 |
5.0 V " " " |
" " " " |
IN " " " |
GND " " " |
GND " " " |
GND " " " |
OUT OUT |
OUT OUT |
" " " " |
G to w G to w G to Y G to Y |
6 6 8 8 |
28 24 37 35 |
" " " " |
||||||||
tPHL5 " " " " " " " |
" " " " " " " " |
89 90 91 92 93 94 95 96 |
IN |
IN |
IN |
IN |
IN |
IN |
IN |
" " " " " " " " |
IN |
GND " " " " " " " |
GND 5.0 V GND 5.0 V GND 5.0 V GND 5.0 V |
GND GND 5.0 V 5.0 V GND GND 5.0 V 5.0 V |
GND " " " 5.0 V " " " |
OUT " " " " " " " |
" " " " " " " " |
Do to w D1 to w D2 to w D3 to w D4 to w D5 to w D6 to w D7 to w |
3 " " " " " " " |
20 " " " " " " " |
" " " " " " " " |
||
tPLH5 " " " " " " " |
" " " " " " " " |
97 98 99 100 101 102 103 104 |
IN |
IN |
IN |
IN |
IN |
IN |
IN |
" " " " " " " " |
IN |
" " " " " " " " |
GND 5.0 V GND 5.0 V GND 5.0 V GND 5.0 V |
GND GND 5.0 V 5.0 V GND GND 5.0 V 5.0 V |
GND " " " 5.0 V " " " |
" " " " " " " " |
" " " " " " " " |
Do to w D1 to w D2 to w D3 to w D4 to w D5 to w D6 to w D7 to w |
" " " " " " " " |
17 " " " " " " " |
" " " " " " " " |
See note at end of device type 02.