MIL-M-38510/118B
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ -55°C ≤ TA ≤ +125°C see figure 9 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Output voltage recovery after output short circuit current |
VOUT (RECOV) |
VIN = -4.25 V, 3/ after IOS1 |
RL = 0.833 n, CL = 10 µF |
04 |
-1.30 |
-1.20 |
V |
VIN = -40 V, 3/ after IOS2 |
RL = 250 n |
-1.30 |
-1.20 |
||||
Voltage start-up |
VSTART |
VIN = -4.25 V |
RL = 0.833 n, CL = 10 µF |
04 |
-1.30 |
-1.20 |
V |
Ripple rejection |
�VIN / �VOUT |
VIN = -6.25 V, 6/ ei = 1 Vrms, at fo = 2400 Hz |
IL = 500 mA, TA = 25°C, see figure 10 |
04 |
50 |
dB |
|
Output noise voltage |
VNO |
VIN = -6.25 V, 4/ see figure 11 |
IL = 100 mA, TA = 25°C |
04 |
120 |
µVrms |
|
Line transient response |
�VOUT / �VIN |
VIN = -6.25 V, 5/ �VIN = -1.0 V, see figure 12 |
IL = 100 mA, TA = 25°C |
04 |
80 |
mV/V |
|
Load transient response |
�VOUT / �IL |
VIN = -6.25 V, 5/ see figure 13 |
IL = 100 mA, �IL = 400 mA TA = 25°C |
04 |
0.15 |
mV/mA |
1/ All tests performed at TA = 125°C may at the manufacturer's option, be performed at TA = 150°C.
Specifications for TA = 125°C shall then apply at TA = 150°C.
2/ Static tests with load currents greater than 5 mA are performed under pulsed conditions defined on figure 9.
3/ Output voltage recovery test shall be performed, with the designated load conditions, immediately after removal of each IOS test forced output voltage condition.
4/ The meter for ei and eo shall have a minimum bandwidth from 10 Hz to 10 kHz and shall measure true rms voltages.
5/ The oscilloscope shall have a bandwidth between 5 and 15 MHz.
6/ The meter for ei and eo shall have a minimum bandwidth from 300 Hz to 10 kHz and shall measure true rms voltage.
13