MIL-M-38510/1188
TA8LE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ -55°C ≤ TA ≤ +125°C see figure 9 and 3.5 unless otherwise specified |
Device type |
Limits |
Unit |
||
Min |
Max |
||||||
Input voltage |
Load current |
||||||
Output voltage |
VOUT |
VIN = -8 V |
IL = 5 mA' 1 A |
02 |
-5.25 |
-4.75 |
V |
VIN = -30 V |
IL = 5 mA' 100 mA |
-5.25 |
-4.75 |
||||
VIN = -38 V |
IL = 1 A |
-31.5 |
-28.5 |
||||
VIN = -10 V' TA = 150°C |
IL = 5 mA |
-5.25 |
-4.75 |
||||
Line regulation |
VRLINE |
-30 V ≤ VIN ≤ -8 V |
IL = 100 mA |
02 |
-150 |
150 |
mV |
-25 V ≤ VIN ≤ -8 V |
IL = 500 mA |
-75 |
75 |
||||
Load regulation |
VRLOAD |
VIN = -10 V |
5 mA ≤ IL ≤ 1 A |
02 |
-100 |
100 |
mV |
VIN = -30 V |
5 mA ≤ IL ≤ 100 mA |
-150 |
150 |
||||
Thermal regulation |
VRTH |
VIN = -15 V' TA = 25°C |
IL = 1 A |
02 |
-50 |
50 |
mV |
Standby current drain |
ISCD |
VIN = -10 V |
IL = 5 mA |
02 |
0.1 |
3.0 |
mA |
VIN = -30 V |
IL = 5 mA |
0.1 |
4.0 |
||||
Standby current drain change versus line voltage |
�ISCD (LINE) |
-30 V ≤ VIN ≤ -8 V |
IL = 5 mA |
02 |
-1.0 |
1.0 |
mA |
Standby current drain change versus load current |
�ISCD (LOAD) |
VIN = -10 V |
5 mA ≤ IL ≤ 1 A |
02 |
-0.5 |
0.5 |
mA |
Control pin current |
ICTL |
VIN = -10 V' TA = 25°C |
IL = 500 mA |
02 |
0.01 |
2.00 |
µA |
VIN = -10 V' -55°C ≤ TA ≤ 125°C |
IL = 500 mA |
0.001 |
3.00 |
See footnotes at end of table.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business