MIL-M-38510/112B
NOTES:
1 All resistor are ±0.1% tolerance and all capacitor are ±10% tolerance.
2 Precautions shall be taken to prevent damage to the D.U.T. during insertion into socket and change of state of relays (i.e. disable voltage supplies, current limit ±VCC, etc.).
3 All relays are shown in the normal de-energized state. The following table shall be used to determine which relays to energize for each test. (For device type 02, use tests 87 and 90 only.)
Channel sep. test no. |
Channels tested |
Relays energized |
|
Driven channel Monitored channel |
|||
87 88 89 |
A to B A to C A to D |
2,3,4,6,8 |
9,12,13,14,15 17,20,21,22,23 25,28,29,30,31 |
90 91 92 |
B to A B to C B to D |
10,11,12,14,16 |
1,4,5,6,7 17,20,21,22,23 25,28,29,30,31 |
93 94 95 |
C to A C to B C to D |
18,19,20,22,24 |
1,4,5,6,7 9,12,13,14,15 25,28,29,30,31 |
96 97 98 |
D to A D to B D to C |
26,27,28,30,32 |
1,4,5,6,7 9,12,13,14,15 |
17,20,21,22,23 |
4 The nulling amplifier shall be a JM38510/10101XXX or equivalent. Saturation of the nulling amplifier is not allowed.
FIGURE 4. Channel separation test circuit. - Continued.
18
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business