TABLE III. Group A inspection for device type 08.
Terminal conditions (pins not designated may be high � 2.4 V or low s 0.8 V; or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Test no. |
IN B |
IN C |
LT |
RBO |
RBI |
IN D |
IN A |
GND |
OUT E |
OUT D |
OUT C |
OUT B |
OUT A |
OUT G |
OUT F |
VCC |
Min |
Max |
|||||
10 Tc = 125°C |
tPHL tPLH |
3003 (Fig. 7) " " " " " " " " " " " " " " " " " " " " " |
156 & 157 158 & 159 160 & 161 162 & 163 164 & 165 166 & 167 168 & 169 170 & 171 172 & 173 174 & 175 176 & 177 178 & 179 180 & 181 182 & 183 184 & 185 186 & 187 188 & 189 190 & 191 192 & 193 194 & 195 196 & 197 198 & 199 200 & 201 |
GND " " " 5.0 V GND 5.0 V GND IN " " " " " " " 5.0 V " " GND GND x GND |
GND " " " 5.0 V 5.0 V 5.0 V GND " " " " 5.0 V 5.0 V 5.0 V IN IN GND GND 5.0 V GND x GND |
5.0 V " " " " " " " " " " " " " " " " " " " IN GND 5.0 V |
OUT IN |
5.0 V " " " " " " GND 5.0 V " " " " " " " " " " " GND x IN |
GND " " " " " " " " " " 5.0 V GND " " " " IN IN IN GND x GND |
IN " " " " " " " GND " " " 5.0 V 5.0 V GND " " " " " " x GND |
GND " " " " " " " " " " " " " " " " " " " " " " |
OUT OUT |
OUT OUT OUT |
OUT OUT |
OUT OUT OUT |
OUT OUT OUT OUT OUT OUT OUT |
OUT OUT |
OUT OUT OUT |
5.0 V " " " " " " " " " " " " " " " " " " " " " " |
IN A to A IN A to D IN A to E IN A to F IN A to A IN A to B IN A to D IN A to RBO IN B to C IN B to F IN B to G IN B to A IN B to F IN B to G IN B to E IN C to D IN C to B IN D to A IN D to B IN D to C LT to A RBO to A RBI to A |
8 " " " " " " " " " " " " " " " " " " " " " " |
144 " " " " " " " " " " " " " " " " " " " " " " |
ns " " " " " " " " " " " " " " " " " " " " " " |
11 |
Same tests, terminal conditions, and limits as subgroup 10 except TC = -55°C. |
11 x = Input may be high level or low level.
21 CKT except B.
31 Output voltages shall be either:
(a) H = 2.4 volts minimum and L = 0.4 volts minimum when using high speed checker double comparator, or
(b) H � 1.5 volts and L s 1.5 volts when using a high speed checker single comparator.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744