MIL-M-38510/10D
NOTES:
1. The pulse generator has the following characteristics: VGEN = 3.0 V minimum,
tTLH (0.7 V to 2.7 V) and tTHL (2.7 V to 0.7 V) ≤ 10 ns, PRR = 1 MHz, and minimum duty cycle = 50%.
2. CL includes probe and jig capacitance.
3. Input - output waveform combination in accordance with the truth tables (see figure 3).
FIGURE 5. Switching times for device types 04 and 05.