TABLE III. Group A inspection for device type 03 Continued.
Terminal conditions (pins not designated may be high � 2.0 V, low s 0.8 V, or open)
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases A,B,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Test no. |
A |
E |
F |
G |
H |
I |
GND |
Y |
J |
K |
B |
C |
D |
VCC |
Min |
Max |
|||||
9 TC=25°C |
tPHL |
3003 Fig. 3 " " |
55 56 57 58 |
IN GND GND GND |
GND IN GND GND |
GND 2.7 V GND GND |
GND GND IN GND |
GND GND 2.7 V GND |
GND GND 2.7 V GND |
GND " " " |
OUT " " " |
GND GND GND IN |
GND GND GND 2.7 V |
2.7 V GND GND GND |
2.7 V GND GND GND |
2.7 V GND GND GND |
5.0 V " " " |
A to Y E to Y G to Y J to Y |
2.0 " " " |
10.0 " " " |
ns " " " |
tPLH |
" " " " |
59 60 61 62 |
IN GND GND GND |
GND IN GND GND |
GND 2.7 V GND GND |
GND GND IN GND |
GND GND 2.7 V GND |
GND GND 2.7 V GND |
" " " " |
" " " " |
GND GND GND IN |
GND GND GND 2.7 V |
2.7 V GND GND GND |
2.7 V GND GND GND |
2.7 V GND GND GND |
" " " " |
A to Y E to Y G to Y J to Y |
" " " " |
12.0 " " " |
" " " " |
|
10 TC=125°C |
tPHL |
" " " " |
63 64 65 66 |
IN GND GND GND |
GND IN GND GND |
GND 2.7 V GND GND |
GND GND IN GND |
GND GND 2.7 V GND |
GND GND 2.7 V GND |
" " " " |
" " " " |
GND GND GND IN |
GND GND GND 2.7 V |
2.7 V GND GND GND |
2.7 V GND GND GND |
2.7 V GND GND GND |
" " " " |
A to Y E to Y G to Y J to Y |
" " " " |
13.0 " " " |
" " " " |
tPLH |
" " " " |
67 68 69 70 |
IN GND GND GND |
GND IN GND GND |
GND 2.7 V GND GND |
GND GND IN GND |
GND GND 2.7 V GND |
GND GND 2.7 V GND |
" " " " |
" " " " |
GND GND GND IN |
GND GND GND 2.7 V |
2.7 V GND GND GND |
2.7 V GND GND GND |
2.7 V GND GND GND |
" " " " |
A to Y E to Y G to Y J to Y |
" " " " |
16.0 " " " |
" " " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business