TABLE III. Group A inspection for device type 03.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.8 V; or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Case 2 1/ |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
|||||||
Test no. |
S |
I0a |
I1a |
Za |
I0b |
I1b |
Zb |
GND |
Zd |
I1d |
I0d |
Zc |
I1c |
I0c |
E |
VCC |
Min |
Max |
|||||
9 TC = 25°C |
tPHL5 |
3003 Fig. 4 " " |
92 |
0.0 V |
2.7 V |
OUT |
GND |
IN |
5.0 V |
E to Za |
2.5 |
6.5 |
ns |
||||||||||
93 |
" |
2.7 V |
OUT |
" |
" |
" |
E to Zb |
" |
" |
" |
|||||||||||||
94 |
" |
" |
OUT |
2.7 V |
" |
" |
E to Zd |
" |
" |
" |
|||||||||||||
95 |
" |
" |
OUT |
2.7 V |
" |
" |
E to Zc |
" |
" |
" |
|||||||||||||
tPLH3 |
" " " " |
96 |
IN |
2.7 V |
0.0 V |
OUT |
" |
0.0 V |
" |
S to Za |
4.0 |
10.0 |
" |
||||||||||
97 |
" |
2.7 V |
0.0 V |
OUT |
" |
" |
" |
S to Zb |
" |
" |
" |
||||||||||||
98 |
" |
" |
OUT |
0.0 V |
2.7 V |
" |
" |
S to Zd |
" |
" |
" |
||||||||||||
99 |
" |
" |
OUT |
0.0 V |
2.7 V |
" |
" |
S to Zc |
" |
" |
" |
||||||||||||
tPHL3 |
" " " " |
100 |
" |
0.0 V |
2.7 V |
OUT |
" |
" |
" |
S to Za |
3.0 |
7.0 |
" |
||||||||||
101 |
" |
0.0 V |
2.7 V |
OUT |
" |
" |
" |
S to Zb |
" |
" |
" |
||||||||||||
102 |
" |
" |
OUT |
2.7 V |
0.0 V |
" |
" |
S to Zd |
" |
" |
" |
||||||||||||
103 |
" |
" |
OUT |
2.7 V |
0.0 V |
" |
" |
S to Zc |
" |
" |
" |
||||||||||||
10 |
Same tests and terminal conditions as subgroup 9, except TC = +125°C and use limits from table I. |
||||||||||||||||||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
1/ For case 2 pins not referenced are N/C.
2/ IIL limits shall be as follows:
Test |
Min/Max limits in mA for circuit |
|||
A |
B |
C |
D |
|
IIL |
-.25/-.60 |
-.03/-.60 |
-.03/-.60 |
0.0/-0.30 |
3/ A = 2.5 V, B = 0.5 V. H � 1.5 V, L s 1.5 V.
4/ Perform function sequence at VCC = 4.5 V and repeat at VCC = 5.5 V.
5/ IOD minimum limit for circuit D shall be 35 mA.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.