TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.8 V; or open).
1/ For cases 2 and X pins not referenced are N/C.
2/ Apply 3.0 V min/5.5 V max, 0 V, 3.0 V min/5.5 V max to MR then 3.0 V min/5.5 V max, 0 V, 3.0 V min/5.5 V max to CP prior to making measurement.
3/ Apply 3.0 V min/5.5 V max, 0 V, 3.0 V min/5.5 V max to CP prior to making measurement.
4/ IIL1 limits shall be as follows:
Parameter |
Test no. |
Min/Max limits in mA for circuit |
||
A |
B |
C |
||
IIL1 |
43 through 52 |
-.25/-.60 |
-.03/-.60 |
-.03/-.60 |
5/ A = 2.5 V minimum, B = 0.5 V maximum, X = don't care. H � 1.5 V, L s 1.5 V.
6/ Perform function sequence at VCC = 4.5 V and repeat at VCC = 5.5 V.
7/ fMAX shall be measured only under the conditions of initial qualification and after process or design changes which may affect this parameter. For all other conditions, fMAX shall be guaranteed, if not tested, to the limits specified in table III, herein.