TA8LE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high 2.0 V, low σ 0.7 V, or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases A,8,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Cases X, 2 1/ |
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
|||||||
Test no. |
1Y |
1A |
18 |
2Y |
2A |
28 |
GND |
3A |
38 |
3Y |
4A |
48 |
4Y |
VCC |
Min |
Max |
|||||
1 Tc = 25°C |
ICCH |
3005 |
49 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
5.5 V |
VCC |
3.2 |
mA |
|||||
ICCL |
3005 |
50 |
4.5 V |
4.5 V |
4.5 V |
4.5 V |
GND |
4.5 V |
4.5 V |
4.5 V |
4.5 V |
5.5 V |
VCC |
5.4 |
mA |
||||||
2 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||
9 Tc = 25°C |
tPHL |
3003 Fig. 3 " " " " " " |
51 |
OUT |
IN |
GND |
GND |
5.0 V |
1A to 1Y |
2 |
16 |
ns |
|||||||||
52 |
OUT |
GND |
IN |
" |
" |
18 to 1Y |
" |
" |
" |
||||||||||||
53 |
OUT |
IN |
GND |
" |
" |
2A to 2Y |
" |
" |
" |
||||||||||||
54 |
OUT |
GND |
IN |
" |
" |
28 to 2Y |
" |
" |
" |
||||||||||||
55 |
" |
IN |
GND |
OUT |
" |
3A to 3Y |
" |
" |
" |
||||||||||||
56 |
" |
GND |
IN |
OUT |
" |
38 to 3Y |
" |
" |
" |
||||||||||||
57 |
" |
IN |
GND |
OUT |
" |
4A to 4Y |
" |
" |
" |
||||||||||||
58 |
" |
GND |
IN |
OUT |
" |
48 to 4Y |
" |
" |
" |
||||||||||||
tPLH |
" " " " " " " " |
59 |
OUT |
IN |
GND |
" |
" |
1A to 1Y |
" |
22 |
" |
||||||||||
60 |
OUT |
GND |
IN |
" |
" |
18 to 1Y |
" |
" |
" |
||||||||||||
61 |
OUT |
IN |
GND |
" |
" |
2A to 2Y |
" |
" |
" |
||||||||||||
62 |
OUT |
GND |
IN |
" |
" |
28 to 2Y |
" |
" |
" |
||||||||||||
63 |
" |
IN |
GND |
OUT |
" |
3A to 3Y |
" |
" |
" |
||||||||||||
64 |
" |
GND |
IN |
OUT |
" |
38 to 3Y |
" |
" |
" |
||||||||||||
65 |
" |
IN |
GND |
OUT |
" |
4A to 4Y |
" |
" |
" |
||||||||||||
66 |
" |
GND |
IN |
OUT |
" |
48 to 4Y |
" |
" |
" |
||||||||||||
10 Tc = 125°C |
tPHL |
" " " " " " " " |
67 |
OUT |
IN |
GND |
" |
" |
1A to 1Y |
" |
26 |
" |
|||||||||
68 |
OUT |
GND |
IN |
" |
" |
18 to 1Y |
" |
" |
" |
||||||||||||
69 |
OUT |
IN |
GND |
" |
" |
2A to 2Y |
" |
" |
" |
||||||||||||
70 |
OUT |
GND |
IN |
" |
" |
28 to 2Y |
" |
" |
" |
||||||||||||
71 |
" |
IN |
GND |
OUT |
" |
3A to 3Y |
" |
" |
" |
||||||||||||
72 |
" |
GND |
IN |
OUT |
" |
38 to 3Y |
" |
" |
" |
||||||||||||
73 |
" |
IN |
GND |
OUT |
" |
4A to 4Y |
" |
" |
" |
||||||||||||
74 |
" |
GND |
IN |
OUT |
" |
48 to 4Y |
" |
" |
" |
||||||||||||
tPLH |
" " " " " " " " |
75 |
OUT |
IN |
GND |
" |
" |
1A to 1Y |
" |
30 |
" |
||||||||||
76 |
OUT |
GND |
IN |
" |
" |
18 to 1Y |
" |
" |
" |
||||||||||||
77 |
OUT |
IN |
GND |
" |
" |
2A to 2Y |
" |
" |
" |
||||||||||||
78 |
OUT |
GND |
IN |
" |
" |
28 to 2Y |
" |
" |
" |
||||||||||||
79 |
" |
IN |
GND |
OUT |
" |
3A to 3Y |
" |
" |
" |
||||||||||||
80 |
" |
GND |
IN |
OUT |
" |
38 to 3Y |
" |
" |
" |
||||||||||||
81 |
" |
IN |
GND |
OUT |
" |
4A to 4Y |
" |
" |
" |
||||||||||||
82 |
" |
GND |
IN |
OUT |
" |
48 to 4Y |
" |
" |
" |
||||||||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55° C. |
1/ For cases X and 2, pins not referenced are NC.
2/ IIL limits in μA shall be as follows:
Parameters |
Circuits |
||||||
A |
8 |
C |
D |
E |
F |
G |
|
IIL |
-0/-360 |
-30/-300 |
-160/-400 |
-120/-360 |
-150/-380 |
-100/-340 |
-160/-400 |
3/ IOS limits for circuits A, 8, C, D, E, and F are -15/-100 mA; for circuit G, -30/-130 mA.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business