TABLE III. Group A inspection for device type 03 - Continued.
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Test No. |
1A |
1Y |
2A |
2Y |
3A |
3Y |
GND |
4Y |
4A |
5Y |
5A |
6Y |
6A |
vCC |
Min |
Max |
Unit |
||||
3 TC = -55°C " " " " " " " " " " " " " |
IIL " " " " " |
3009 " " " " " |
103 104 105 106 107 108 |
0.4 v |
0.4 v |
0.4 v |
GND " " " " " |
0.4 v |
0.4 v |
0.4 v |
5.5 v " " " " " |
1A 2A 3A 4A 5A 6A |
-0.6 " " " " " |
-1.50 " " " " " |
mA " " " " " |
||||||
ICEX " " " " " |
109 110 111 112 113 114 |
1.4 v |
4.5 v |
1.4 v |
4.5 v |
1.4 v |
4.5 v |
" " " " " " |
4.5 v |
1.4 v |
4.5 v |
1.4 v |
4.5 v |
1.4 v |
4.5 v " " " " " |
1Y 2Y 3Y 4Y 5Y 6Y |
50 " " " " " |
µA " " " " " |
|||
ICCL |
3005 |
115 |
" |
5.0 v |
vCC |
19.5 |
mA |
||||||||||||||
ICCH1 |
" |
116 |
GND |
GND |
GND |
" |
GND |
GND |
GND |
5.0 v |
vCC |
8.82 |
mA |
||||||||
ICCH2 |
" |
117 |
GND |
GND |
GND |
" |
GND |
GND |
GND |
8.0 v |
vCC |
16.5 |
mA |
||||||||
9 TC = 25°C " " " " " " " " " " |
tPHL " " " " " |
3003 (Fig. 4) " " " " |
118 119 120 121 122 123 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
5.0 v " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
10 " " " " " |
30 " " " " " |
ns " " " " " |
tPLH " " " " " |
" " " " " " |
124 125 126 127 128 129 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
25 " " " " " |
80 " " " " " |
" " " " " " |
|
10 TC = 125°C " " " " " " " " " " |
tPHL " " " " " |
" " " " " " |
130 131 132 133 134 135 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
10 " " " " " |
35 " " " " " |
" " " " " " |
tPLH " " " " " |
" " " " " " |
136 137 138 139 140 141 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
25 " " " " " |
112 " " " " " |
" " " " " " |
|
11 TC = -55°C " " " " " " " " " " |
tPHL " " " " " |
3003 " " " " " |
142 143 144 145 146 147 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
10 " " " " " |
40 " " " " " |
" " " " " " |
tPLH " " " " " |
" " " " " " |
148 149 150 151 152 153 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
25 " " " " " |
80 " " " " " |
" " " " " " |
1/ Pins not designated may be HIGH level logic, LOW level logic or open.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business