TABLE III. Group A inspection for device type 01 - Continued. Terminal conditions (pins not designated may be H � 2.0 V, L ≤ 0.8 V, or open)
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Test no. |
BD |
R0(1) |
R0(2) |
NC |
VCC |
R9(1) |
R9(2) |
QC |
QB |
GND |
QD |
QA |
NC |
Input A |
Min |
Max |
|||||
7 TC= 25°C |
Truth table tests 6/ |
137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 |
B 5/ A A B B A A B B A A A B B A A B |
B 5/ " " " " " " " " " " " " " " A A |
B 5/ " " " " " " " " " " " " " " A A |
4.5 V " " " " " " " " " " " " " " " " |
B 5/ " " " " " " " " " A A A B " " " |
B 5/ " " " " " " " " " A A A B " " " |
L L L H H H H H H H L L L L L L L |
H H H L L L L H H H L L L L L L L |
GND " " " " " " " " " " " " " " " " |
L L L L L L L L L L H H H H H L L |
L H H L L H H L L H H H H H L L L |
A 5/ B A B A B A B A B A A B A B A B |
All outputs " " " " " " " " " " " " " " " |
H or L As shown 4/ " " " " " " " " " " " " " " " |
|||||
8 |
Same tests, terminal conditions and limits as for subgroup 7 except TC=125°C and -55°C. |
||||||||||||||||||||
9 TC= 25°C |
fMAX 7/ |
(Fig. 3) |
154 |
GND |
GND |
5.0 V |
GND |
GND |
GND |
OUT |
IN |
QA |
6 |
MHz |
|||||||
tPLH1 |
3003 (Fig. 3) " " |
155 156 157 158 |
QA " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
OUT |
OUT |
" " " " |
OUT |
OUT |
" " " " |
QA QB QC QD |
85 170 255 340 |
ns " " " |
||||
tPHL1 |
" " " " |
159 160 161 162 |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
OUT |
OUT |
" " " " |
OUT |
OUT |
" " " " |
QA QB QC QD |
85 170 255 340 |
" " " " |
||||
10 TC=+125°C |
fMAX 7/ |
" |
163 |
" |
" |
" |
" |
" |
" |
OUT |
" |
QA |
5 |
MHz |
|||||||
tPLH1 |
" " " " |
164 165 166 167 |
QA " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
OUT |
OUT |
" " " " |
OUT |
OUT |
" " " " |
QA QB QC QD |
125 255 380 510 |
ns " " " |
||||
tPHL1 |
" " " " |
168 169 170 171 |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
OUT |
OUT |
" " " " |
OUT |
OUT |
" " " " |
QA QB QC QD |
125 255 380 510 |
" " " " |
||||
11 |
Same tests, terminal conditions and limits as for subgroup 7 except TC= -55°C. |
1/ Momentarily apply 2.0 V, then ground prior to taking measurements to set the device in desired state. Maintain ground for measurement.
2/ Same as 1/, except apply one pulse after reset (R0) pulses.
3/ Same as 1/, except apply two pulses after reset (R0) pulses.
4/ Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.3 V maximum when using a high speed checker double comparator; or (b) H � 1.5 V and L ≤ 1.5 V when using a high speed checker single comparator.
5/ Input voltages shown are: A = 2.4 V; B = 0.3 V.
6/ Only a summary of attributes data is required.
7/ fMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business