MIL-M-38510/25E
TABLE II. Electrical test requirements.
MIL-PRF-38535 test requirements |
Subgroup (see table III) |
|
Class S devices |
Class B devices |
|
Interim electrical parameters (Pre Burn-In) (Method 5004) |
1 |
1 |
Final electrical test parameters |
1*, 2, 3, 7, 9, 10, 11 |
1*, 2, 3, 7, 9 |
Group A test requirements |
1, 2, 3, 7, 8, 9, 10, 11 |
1, 2, 3, 7, 8, 9, 10, 11 |
Group B electrical test parameters when using the method 5005 QCI option |
1, 2, 3, 7, 8, 9, 10, 11 |
N/A |
Group C end-point electrical parameters |
1, 2, 3, 7, 8, 9, 10, 11 |
1, 2, 3 |
Group D end-point electrical parameters |
1, 2, 3 |
1, 2, 3 |
*PDA applies to subgroup 1
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table III.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group number 8 (see MIL-PRF-38535, appendix A).
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not effect the form, fit, or function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535 and shall be conducted on all devices prior to qualification and conformance inspection. The following additional criteria shall apply:
a. The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under document control by the device manufacturer's Technology Review Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1015 of MIL-STD-883.
b. Interim and final electrical test parameters shall be as specified in table II, except interim electrical parameters test prior to burn-in is optional at the discretion of the manufacturer.
c. Additional screening for space level product shall be as specified in MIL-PRF-38535.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business