TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V, low s 0.8 V, or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases C and D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Test no. |
1C |
1A |
1Y |
2C |
2A |
2Y |
GND |
3Y |
3A |
3C |
4Y |
4A |
4C |
VCC |
Min |
Max |
|||||
10 Tc = 125°C |
tPZH |
3003 Fig. 2 " " |
94 |
IN |
5.0 V |
OUT |
GND |
5.0 V |
1C to 1Y |
2 |
20 |
ns |
|||||||||
95 |
IN |
5.0 V |
OUT |
" |
" |
2C to 2Y |
" |
" |
" |
||||||||||||
96 |
" |
OUT |
5.0 V |
IN |
" |
3C to 3Y |
" |
" |
" |
||||||||||||
97 |
" |
OUT |
5.0 V |
IN |
" |
4C to 4Y |
" |
" |
" |
||||||||||||
tPZL |
" " " " |
98 |
IN |
0.0 V |
OUT |
" |
" |
1C to 1Y |
2 |
30 |
" |
||||||||||
99 |
IN |
0.0 V |
OUT |
" |
" |
2C to 2Y |
" |
" |
" |
||||||||||||
100 |
" |
OUT |
0.0 V |
IN |
" |
3C to 3Y |
" |
" |
" |
||||||||||||
101 |
" |
OUT |
0.0 V |
IN |
" |
4C to 4Y |
" |
" |
" |
||||||||||||
tPHZ |
" " " " |
102 |
IN |
5.0 V |
OUT |
" |
" |
1C to 1Y |
2 |
21 |
" |
||||||||||
103 |
IN |
5.0 V |
OUT |
" |
" |
2C to 2Y |
" |
" |
" |
||||||||||||
104 |
" |
OUT |
5.0 V |
IN |
" |
3C to 3Y |
" |
" |
" |
||||||||||||
105 |
" |
OUT |
5.0 V |
IN |
" |
4C to 4Y |
" |
" |
" |
||||||||||||
tPLZ |
" " " " |
106 |
IN |
0.0 V |
OUT |
" |
" |
1C to 1Y |
2 |
20 |
" |
||||||||||
107 |
IN |
0.0 V |
OUT |
" |
" |
2C to 2Y |
" |
" |
" |
||||||||||||
108 |
" |
OUT |
0.0 V |
IN |
" |
3C to 3Y |
" |
" |
" |
||||||||||||
109 |
" |
OUT |
0.0 V |
IN |
" |
4C to 4Y |
" |
" |
" |
||||||||||||
11 |
Same tests, terminal conditions and limits as subgroup 10, except TC = -55°C. |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business