MIL-M-38510/128A
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as follows:
a. End point electrical parameters shall be as specified in table II herein.
b. The steady-state life test duration, test condition, and test temperature, or approved alternatives shall be as
specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under document control by the device manufacturer's Technology Review Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1005 of MIL-STD-883.
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535. End point electrical parameters shall be as specified in table II herein.
Table IV. Groups C end point electrical parameters.
Device type |
Characteristic |
Symbol |
Delta limits 1/ |
Limits |
Unit |
|
Min |
Max |
|||||
01 |
Output voltage 1 VO = 10 V VO = 10 V |
VOUT1 |
±0.05% |
9.965 |
10.035 |
V |
02 |
" |
9.985 |
10.015 |
" |
||
01 |
Output voltage 2 VO = 7.5 V VO = 7.5 V |
VOUT2 |
" |
7.474 |
7.526 |
" |
02 |
" |
7.488 |
7.512 |
" |
||
01 |
Output voltage 3 VO = 5.0 V VO = 5.0 V |
VOUT3 |
" |
4.982 |
5.018 |
" |
02 |
" |
4.991 |
5.009 |
" |
||
01 |
Output voltage 4 VO = 2.5 V VO = 2.5 V |
VOUT4 |
" |
2.4913 |
2.5088 |
" |
02 |
" |
2.4952 |
2.5048 |
" |
1/ Delta limits apply to the measured value (see delta limit definition in MIL-PRF-38535).
4.5 Methods of inspection. Methods of inspection shall be as specified and as follows.
4.5.1 Voltage and current. All voltage values given are referenced to the microcircuit ground terminals. Currents given are conventional current and positive when flowing into the referenced terminal.
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD personnel, these personnel need to contact the responsible packaging activity to ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory Control Point's packaging activity within the Military Department of Defense Agency, or within the Military Department's System Command. Packaging data retrieval is available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.
6. NOTES
6.1 Intended use. Microcircuits conforming to this specification are intended for original equipment design applications and logistic support of existing equipment.