TAaLE III. Group A inspection - Continued.
Subgroup |
Symbol |
MIL-STD-883 method |
Test |
Condition 1/ |
Device type |
Limits 2/ |
Unit |
|
Min |
Max |
|||||||
6 TA = -55qC |
AV+ |
4004 |
44 |
Figure 4, ±VCC = ±18 V |
01,02,03 |
0.999 |
1.000 |
V/V |
AV- |
4004 |
45 |
Figure 4, ±VCC = ±18 V |
01,02,03 |
0.999 |
1.000 |
V/V |
|
VOPP1 |
4004 |
46 |
RL = 10 kn, booster open, ±VO = ±10 V |
01,02,03 |
20 |
V |
||
VOPP2 |
4004 |
47 |
RL = 3.3 kn, ±VO = ±10 V, 100 n from booster to -VCC |
01,02,03 |
20 |
V |
||
7 TA = +25qC |
TR rise time |
48 |
Figure 5 |
01,02,03 |
44 |
ns |
||
TR overshoot |
49 |
Figure 5 |
01,02,03 |
40 |
% |
|||
SR(+) |
4002 |
50 |
Figure 5 |
01 |
7 |
V/µs |
||
02,03 |
20 |
|||||||
SR(-) |
4002 |
51 |
Figure 5 |
01 |
7 |
V/µs |
||
02,03 |
20 |
|||||||
aw |
52 |
Figure 5 |
01,02,03 |
8 |
MHz |
|||
CS |
53 |
Figure 6 |
03 |
90 |
da |
|||
8 TA = +125qC |
TR rise time |
54 |
Figure 5 |
01,02,03 |
44 |
ns |
||
TR overshoot |
55 |
Figure 5 |
01,02,03 |
50 |
% |
|||
SR(+) |
4002 |
56 |
Figure 5 |
01 |
7 |
V/µs |
||
02,03 |
20 |
|||||||
SR(-) |
4002 |
57 |
Figure 5 |
01 |
7 |
V/µs |
||
02,03 |
20 |
|||||||
aw |
58 |
Figure 5 |
01,02,03 |
8 |
MHz |
|||
CS |
59 |
Figure 6 |
03 |
90 |
da |
|||
8 TA = -55qC |
TR rise time |
60 |
Figure 5 |
01,02,03 |
44 |
ns |
||
TR overshoot |
61 |
Figure 5 |
01,02,03 |
50 |
% |
|||
SR(+) |
4002 |
62 |
Figure 5 |
01 |
7 |
V/µs |
||
02,03 |
20 |
|||||||
SR(-) |
4002 |
63 |
Figure 5 |
01 |
7 |
V/µs |
||
02,03 |
20 |
|||||||
aw |
64 |
Figure 5 |
01,02,03 |
8 |
MHz |
|||
CS |
65 |
Figure 6 |
03 |
90 |
da |
1/ Complete terminal conditions shall be as specified on figure 3, unless otherwise specified.
2/ Limits apply to both halves of device type 03, independently.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business