TABLE III. Group A inspection for device type 01 and 02. - Continued
Terminal conditions (High > 2.0 V or Low < 0.8 V or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
Unit |
||||
Test No. |
1A |
1Y |
2A |
2Y |
3A |
3Y |
GND |
4Y |
4A |
5Y |
5A |
6Y |
6A |
VCC |
|||||||
10 TC = +125°C " " " " " " " " " " |
tPHL " " " " " |
3003 (Fig 3) " " " " |
57 58 59 60 61 62 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
GND " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
5.0 V " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
3 " " " " " |
30 " " " " " |
ns " “ “ “ “ |
tPLH " " " " " |
" " " " " " |
63 64 65 66 67 68 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
" " " " " " |
25 " " " " " |
" " " " " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |