TABLE III. Group A inspection for device type 01. Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL- STD- 883 method |
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case G |
--- |
2 |
1 |
6 |
5 |
--- |
4 |
--- |
--- |
5 |
--- |
7 |
--- |
8 |
|||||||
Case M |
1 |
--- |
12 |
3 |
2, 4 |
7 |
5 |
9 |
--- |
6, 8 |
--- |
10 |
--- |
11 |
Min |
Max |
|||||
Test no. |
NC |
NC |
1Y |
NC |
1A |
NC |
vEE |
NC |
NC |
2A |
NC |
2Y |
NC |
vCC |
|||||||
1 TC= 25°C " " " " " " " " " |
vOL vOL |
3007 3007 |
1 2 |
-9.5 v |
-12 v " |
-9.5 v |
5.0 v " |
1Y 2Y |
-11.0 -11.0 |
v v |
|||||||||||
vOH vOH |
3006 3006 |
3 4 |
-11.6 v |
" " |
-11.6 v |
" " |
1Y 2Y |
4.0 4.0 |
v v |
||||||||||||
IIH IIH |
3010 3010 |
5 6 |
-11 v |
-9.5 v |
" " |
-9.5 v |
-11 v |
" " |
1A 2A |
15 15 |
mA mA |
||||||||||
IIL IIL |
3009 3009 |
7 8 |
+4 v |
-12 v |
" " |
-12 v |
+4 v |
" " |
1A 2A |
-10 -10 |
mA mA |
||||||||||
ICCL ICCL |
3005 3005 |
9 10 |
-17.5 v -20 v |
-20 v -20 v |
-20 v -17.5 v |
0 v 0 v |
vCC vCC |
40 40 |
mA mA |
||||||||||||
ICCH |
3005 |
11 |
-20 v |
-20 v |
-20 v |
0 v |
vCC |
100 |
mA |
||||||||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = 125°C and the ICCH test limit maximum shall be 500 µA. |
||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C. |
||||||||||||||||||||
9 TC= 25°C " " " " " " |
tPHL tPHL |
3003 Fig. 3 |
12 13 |
OUT |
IN |
-20 v " |
IN |
OUT |
0 v " |
1Y 2Y |
12 12 |
ns " |
|||||||||
tPLH tPLH |
" " |
14 15 |
OUT |
IN |
" " |
IN |
OUT |
" " |
1Y 2Y |
15 15 |
" " |
||||||||||
tTHL tTHL |
3004 Fig. 3 |
16 17 |
OUT |
IN |
" " |
IN |
OUT |
" " |
1Y 2Y |
35 35 |
" " |
||||||||||
tTLH tTLH |
" " |
18 19 |
OUT |
IN |
" " |
IN |
OUT |
" " |
1Y 2Y |
25 25 |
" " |
||||||||||
10 |
Same tests, terminal conditions and limits as for subgroup 9, except TC = +125°C. |
||||||||||||||||||||
11 |
Same tests, terminal conditions and limits as for subgroup 9, except TC = -55°C. |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.