TA8LE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL- STD- 883 method |
Case A,8,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Case C |
2 |
3 |
1 |
14 |
4 |
5 |
6 |
10 |
8 |
9 |
7 |
11 |
12 |
13 |
Min |
Max |
Unit |
||||
Test No. |
1A |
18 |
1Y |
vCC |
2Y |
2A |
28 |
3Y |
3A |
38 |
GND |
4A |
48 |
4Y |
|||||||
9 TC = 25°C " " " " " " |
tPHL " " " |
3003 (Fig. 3) " " |
43 44 45 46 |
IN |
GND |
OUT |
5.0v " " " |
OUT |
IN |
GND |
OUT |
IN |
GND |
GND " " " |
IN |
GND |
OUT |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y |
3 " " " |
66 " " " |
ns " " " |
tPHL " " " |
" " " " |
47 48 49 50 |
IN |
GND |
OUT |
" " " " |
OUT |
IN |
GND |
OUT |
IN |
GND |
" " " " |
IN |
GND |
OUT |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y |
3 " " " |
60 " " " |
" " " " |
|
10 TC=125°C " " " " " " |
tPLH " " " |
" " " " |
51 52 53 54 |
IN |
GND |
OUT |
" " " " |
OUT |
IN |
GND |
OUT |
IN |
GND |
" " " " |
IN |
GND |
OUT |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y |
3 " " " |
99 " " " |
" " " " |
tPLH " " " |
" " " " |
55 56 57 58 |
IN |
GND |
OUT |
" " " " |
OUT |
IN |
GND |
OUT |
IN |
GND |
" " " " |
IN |
GND |
OUT |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y |
3 " " " |
90 " " " |
" " " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.