TABLE III. Group A inspection for device type 04 - Continued.
Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
|||
Test No. |
2Y |
2W |
B |
2C0 |
2C1 |
2C2 |
2C3 |
GND |
1C3 |
1C2 |
1C1 |
1C0 |
A |
1W |
1Y |
VCC |
Min |
Max |
Unit |
|||||
1 TC = 25°C " " " " " " " " " " " " " |
IIH2 " " " " " " " " " |
3010 " " " " " " " " " |
39 40 41 42 43 44 45 46 47 48 |
5.5 V " " GND GND 5.5 V 5.5 V GND " |
5.5 V |
5.5 V |
5.5 V |
5.5 V |
GND " " " " " " " " " |
5.5 V |
5.5 V |
5.5 V |
5.5 V |
5.5 V 5.5 V GND 5.5 V GND 5.5 V GND 5.5 V GND |
5.5 V " " " " " " " " " |
A B 1C0 1C1 1C2 1C3 2C0 2C1 2C2 2C3 |
100 " " " " " " " " " |
ns " " " " " " " " " |
||||||
IOS " " " |
3011 " " " |
49 50 51 52 |
GND |
GND |
" " " " |
GND 5.5 V |
GND " |
GND " |
GND " |
" " " " |
GND GND |
GND GND |
GND GND |
GND 5.5 V |
" " " " |
GND |
GND |
" " " " |
1W 1Y 2W 2Y |
-20 " " " |
-120 " " " |
mA " " " |
||
ICC |
3005 |
53 |
" |
5.5 V |
" |
" |
" |
" |
GND |
GND |
GND |
5.5 V |
" |
" |
VCC |
45 |
" |
|||||||
2 |
Same tests, terminal conditions and limits as subgroup 1, except TC = 125°C and VIC tests are omitted. |
|||||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as subgroup 1, except TC = -55°C and VIC tests are omitted. |
|||||||||||||||||||||||
7 TC = 25°C " " " " " " |
Truth table test " " " " " |
54 55 56 57 58 59 60 61 |
L 2/ H L H L H L H |
H L H L H L H L |
B 1/ " " " A " " " |
B A |
B A |
B A |
B A |
GND " " " " " " " |
B A |
B A |
B A |
B A |
B B A A B B A A |
H L H L H L H L |
L H L H L H L H |
4.5 V " " " " " " " |
2/ |
|||||
8 |
Repeat subgroup 7 at TC = 125°C and TC = -55°C. |
|||||||||||||||||||||||
9 TC = 25°C " " " " " " |
tPHL1 " " " " " " " |
3003 (Fig 5) " " " " " " |
62 63 64 65 66 67 68 69 |
OUT " " " |
GND GND 5.0 V 5.0 V GND GND 5.0 V 5.0 V |
IN |
IN |
IN |
IN |
GND " " " " " " " |
IN |
IN |
IN |
IN |
GND 5.0 V GND 5.0 V GND 5.0 V GND 5.0 V |
OUT " " " |
5.0 V " " " " " " " |
1C0 to 1Y 1C1 to 1Y 1C2 to 1Y 1C3 to 1Y 2C0 to 2Y 2C1 to 2Y 2C2 to 2Y 2C3 to 2Y |
3 " " " " " " " |
29 " " " " " " " |
ns " " " " " " " |
See note at end of device type 04.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business